我用自己的c程序生成Analyze格式的digital phantom,然后用xmedcon转换成interfile格式,在读入gate的时候经常出错。最后把gate例子里面的hof.h33文件修改成需要的参数,顺利通过。现把修改后的interfile的header发在这里,红色部分为需要修改的:

!INTERFILE :=
!imaging modality := nucmed
!originating system := greetings
!version of keys := 3.3
date of keys := 1996:09:24
conversion program := (X)MedCon
program author := Erik Nolf
program version := 0.7.4
program date := 2002:02:18
;
!GENERAL DATA :=
!data offset in bytes := 0
!name of data file := Point000.i33
patient name := hf
!patient ID := 271097
patient dob := 0000:00:00
patient sex := Unknown
!study ID := myPhantom
exam type := Spect study
data compression := none
data encode := none
;
!GENERAL IMAGE DATA :=
!type of data := Tomographic
!total number of images := 64
study date := 1997:11:28
study time := 00:00:00
imagedata byte order := BIGENDIAN
;
number of energy windows := 1
;
energy window [1] :=
energy window lower level [1] :=
energy window upper level [1] :=
flood corrected := N
decay corrected := N
;
!SPECT STUDY (general) :=
number of detector heads := 1
;
!number of images/energy window := 64
!process status := Reconstructed
!matrix size [1] := 64
!matrix size [2] := 64
!number format := unsigned integer
!number of bytes per pixel := 2
scaling factor (mm/pixel) [1] := +1.000000e-01
scaling factor (mm/pixel) [2] := + 1.000000e-01
!number of projections := 64
!extent of rotation :=
!time per projection (sec) := 0
study duration (sec) := 0
!maximum pixel count := +1.000000e+01
patient orientation := head_in
patient rotation := supine
;
!SPECT STUDY (reconstructed data) :=
method of reconstruction := Unknown
!number of slices := 64
number of reference frame := 0
slice orientation := Transverse
slice thickness (pixels) := +1.000000e+00
centre-centre slice separation (pixels) := +1.000000e+00
filter name := Unknown
filter parameters := Cutoff
method of attenuation correction := measured
scatter corrected := N
oblique reconstruction := N